5 web raid management software - setting – HighPoint NA762TB User Manual
Page 31

HighPoint Technologies Inc. 31
4.4 Logical - Rescan
When hot-plugging a single device or RAID array, the Rescan button prompts the RAID controller to
scan for device changes.
4.5 Logical - Beeper Mute
This will temporarily disable the internal speaker on the RAID controller.
5 Web RAID Management Software - Setting
This tab displays various controller settings and options:
5.1 Setting - System
A. Enable auto rebuild: If enabled, any new disk attached to the RAID controller will be
used to rebuild the critical RAID array.
Note: The new disk needs to be equal to or larger than the
minimum capacity among the remaining disk members of the
array.
B. Enable Continue
Rebuilding on error:
Enabled by default. If disabled, the WebGUI will ignore bad
sectors/read failures and allow the rebuild process to continue.
Warning: this option should only be enabled in the case of an
emergency – data inconsistency or data loss may result. Review
the Event Log before enabling this option, and check for HDD bad