Display Settings
Select Parameters to Display
Use the DSEL command to select the parameters that are displayed on
the transmitter screen. You can select parameters by abbreviation. If only
one parameter is selected, it is shown vertically centered on the
transmitter screen.
DSEL [Q1 Q2 Q3]
where
Q1 = First parameter to show on the screen. Available parameters
are:
out1
same parameter as analog output channel 1
out2
same parameter as analog output channel 2
out3
same parameter as analog output channel 3
CO2
carbon dioxide level
CO2_10
carbon dioxide level in 10 ppm steps
RH
relative humidity
T
temperature
Tdf
dew/frostpoint temperature
Td
dewpoint temperature
Tw
wetbulb temperature
h
enthalpy
x
mixing ratio
a
absolute humidity
dTd
dew/frostpoint depression
Q2 = Second parameter to show on the screen. Available
parameters are the same as for Q1.
Q3 = Third parameter to show on the screen. Available parameters
are the same as for Q1.
Example (show currently displayed parameters):
>pass 9000
>dsel
Quant 1 : RH
Quant 2 : T
Quant 3 : CO2
Example (change display to only show CO2):
>dsel CO2
OK