fACts to ConsIdEr ABout thE LoCAtIon
Carefully choose a location for the new water heater. The placement
is a very important consideration for the safety of the occupants in
the building and for the most economical use of the water heater.
Whether replacing an old water heater or putting the water heater in
a new location, the following critical points must be observed. The
water heater must be located:
• On a level surface. Shim the channel type skid base as necessary
if levelling is required.
LoCAtInG thE nEw wAtEr hEAtEr
• Near a floor drain. The heater should be located in an area where
leakage of the tank or connections will not result in damage to
the area adjacent to the heater or to lower floors of the structure.
• Close to the point of major hot water usage and the power supply.
• Hot water piping and branch circuit wiring should be as short
as possible.
• Insulate hot and cold water piping where heat loss and
condensation may be a problem.
• Heater construction permits installation, maintenance, and
service work to be performed through the front control panel.
• Suggested clearances from adjacent surfaces are 12 inches
on top, 30 inches in front for access to the unit.
• The heater may be installed on or against combustible surfaces.
The left side and back may be placed flush against adjacent
surfaces.
• The temperature of the space in which the water heater is installed
must not go below 32°F or above 122°F.
- CSB 120 45 IFE CSB 120 405 IFE CSB 120 36 IFE CSB 120 30 IFE CSB 120 27 IFE CSB 120 24 IFE CSB 120 18 IFE CSB 120 15 IFE CSB 120 135 IFE CSB 120 12 IFE CSB 120 9 IFE CSB 120 6 IFE CSB 82 54 IFE CSB 82 45 IFE CSB 82 405 IFE CSB 82 36 IFE CSB 82 30 IFE CSB 82 27 IFE CSB 82 24 IFE CSB 82 18 IFE CSB 82 15 IFE CSB 82 135 IFE CSB 82 12 IFE CSB 82 9 IFE CSB 82 6 IFE CSB 52 54 IFE CSB 52 45 IFE CSB 52 405 IFE CSB 52 36 IFE CSB 52 30 IFE CSB 52 27 IFE CSB 52 24 IFE CSB 52 18 IFE CSB 52 15 IFE CSB 52 135 IFE CSB 52 12 IFE CSB 52 9 IFE CSB 52 6 IFE