ThE ProCESS For LIME SCALE rEMoVAL IS AS FoLLowS:

1. Turn off electrical disconnect switch.

2. Drain the heater following DRAINING instructions.

3. Open front panel.

4. Disconnect the element wiring. Try not to disturb the wiring

unnecessarily and reconnection will be easier.

5. Unscrew each element.

6. Remove the elements and gaskets from the openings.

• Use a twisting, pulling action to remove elements scaled beyond

the size of the tank openings.

• Brush loose scale from elements.

7. Lime scale removal:

• Place limed ends of heating elements into UN•LIME delimer and

allow scale to dissolve. Do not permit delimer or water to contact

heating element electrical terminals.

• Silicates, sulfates, and aluminates must be removed by scraping

or other mechanical means. Lime scale dissolvents will

not remove these types of scale which are occasionally

encountered.

Call the toll free phone number on the back cover of this Instruction

Manual to purchase UN-LIME and heating element gaskets.

oThEr SCALE rEMoVAL:

1. Flush cleaned ends of elements with water when deliming or

cleaning is completed.

2. Remove sediment and scale from the tank bottom through

the access provided by the element openings or drain valve

opening.

• The cold water inlet valve and drain valve may be opened to

aid the cleanout process.

3. Clean remaining gasket material from tank and element flanges

Do not reuse original element gaskets.

4. Put new gaskets on each element and install into tank openings.

• Uniformly tighten element bolts. Torque to approximately

32 ft./lbs.

5. Attach element wires to connection points from which they were

removed.

6. Follow FILLING instructions to restore hot water service.

• Check for water leaks around elements and proper operation

when heater is filled.

• Close the front panel.