47
FX2012MT
AC Max = 12AAC (Default = 10AAC)
DC Max = 100ADC
FX2524MT
AC Max = 14AAC (Default = 12AAC)
DC Max = 55ADC
FX2532MT
AC Max = 14AAC (Default = 12AAC)
DC Max = 40ADC
FX3048T
AC Max = 14AAC (Default = 12AAC)
DC Max = 35ADC
VFX2812M
AC Max = 16AAC (Default = 14AAC)
DC Max = 125ADC
VFX3524M
AC Max = 20AAC (Default = 18AAC)
DC Max = 85ADC
VFX3232M
AC Max = 20AAC (Default = 18AAC)
DC Max = 60ADC
VFX3648
AC Max = 20AAC (Default = 18AAC)
DC Max = 45ADC
AC INPUT FREQUENCY RANGE
NOTE: If the AC input source is out of the range noted below, the FX will not connect or stay connected.
All FX Models
56 - 64 Hz
MAXIMUM AC OUTPUT CURRENT
This is the amount of surge current that the FX will quickly supply for a split second. Depending on the
size of the surge, the FX can be overloaded for a minimum time of 5 seconds to a maximum time of 30
minutes.
All 12 VDC FXs
56AAC per FX for 1 millisecond
All Other FXs
70AAC per FX for 1 millisecond
MAXIMUM CONTINUOUS OUTPUT POWER
An FX Series Inverter/Charger’s model number indicates its maximum continuous output power by
changing the last two digits to zeros. For instance, an FX2012MT has a maximum continuous output
power of 2000VA (volt-amps).
FX2012MT
2000VA (VA = volt-Amps)
FX2024MT 2000VA
FX2532MT 2500VA
FX2548T 2500VA
VFX2812M 2800VA
VFX3524M 3500VA
VFX3232M 3200VA
VFX3648 3600VA
MAXIMUM AND DEFAULT AC INPUT AND DC (bulk stage) OUTPUT VALUES