Actron KAL9640B User Manual
Page 46
![background image](/manuals/405667/46/background.png)
Global OBDII Diagnostics
4 – 12 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
4 4
Select Record Data from OBDII
Function List and press
ENTER.
Follow all instructions on display.
Scan tool asks vehicle to provide global
PIDs vehicle supports.
✓
Scan tool can maintain only one recording per group. Make sure to
thoroughly review old recording before erasing.
If a recording currently exists in
memory, a message prompting to erase
data is displayed.
After list is generated, scan tool prompts to select type of data to record. Refer
to “Viewing Data” on page 3-9 to setup Entire or Custom Data Lists.
On next screen, select a triggering
method. Manual Trigger allows
technician to use
ENTER key. Trigger
On Codes automatically triggers when
a DTC is indicated by vehicle.
Once trigger method is selected, scan tool will begin recording data. When
trigger event (either a DTC or a Press of
ENTER key) occurs, time is recorded
and data from last five frames are saved. Data will continue to be saved until
either record memory is full or technician presses
ENTER.
OBDII Function List
?
` 10)Record Data ]
11)Vehicle Info
[
12)Modules Present ~
Validating PID Map
PID 23 of 99
Please Wait
Cannot Record. Old
Recording Filled Up
Memory. Erase Old?
YES
~
Pick Trigger Method
`1)Manual Trigger
2)Trigger On Codes
** INITIALIZING **
PRETRIG FRAME:-5
BACK To Exit
~
**Ready To Record**
Press ENTER Anytime
To Start Recording.
Stops Automatically~