Installation, 1 mounting locations, 2 wiring method, wiring distance – Aiphone JK-1MED User Manual

Page 3: 3 cable, Ab c

background image

- 3 -

English

Fr

ançais

Neder

lands

2

INSTALLATION

2-1 Mounting locations

1

Install the master monitor station in a place

where the screen is not exposed to direct
sunlight.

2

The master monitor station has switches on

both sides. Allow at least 5 cm (2") of open
space on either side.

3

Allow at least 15 cm (6") of vertical open

space from the center of the mounting
bracket in order to mount the master
monitor station.

+ 5 cm

(2")

+ 5 cm

(2")

JK-1MED

2

3

+ 15 cm

(6")

2-2 Wiring method, wiring distance

Wire the units from station-to-station (daisy-chained).

Ø 0,65 mm

22 AWG

Ø 1,0 mm

18 AWG

A

50 m

165'

100 m

330'

B

5 m

16'

10 m

33'

C

75 m

245'

150 m

490'

JK-1HD

JK-1SD

JK-1MED

JK-DA

JK-DV

JK-DVF

2

4

PS18

PS-1820

PS-1810DIN

PS-1820DIN

A

B

C

IER-2

2-3 Cable

1

Use PVC jacket with PE (polyethylene) insulated cable

(x2)

2

Never use individual conductors, twisted pair cable or coaxial cable.

3

When using a cable with unused conductors, terminate both ends of

the unused pair(s) with a 120 resistor .

JK-1MED

JK-1HD/JK-1SD

120

120

+

-

A1

A2

B1

B2

L
L

S
S

+

-

SW

SW

B1