26

).

Battery-backed write cache

The HP BBWC protects against hard boot, power, controller, and system board failures. The server
supports the following battery-backed options:

256-MB BBWC option (ships with the server)

512-MB BBWC option

The BBWC consists of two parts: a battery pack and a storage cache module.
Along with the cache module, the battery pack provides transportable data protection, increases overall

controller performance, and maintains any cached data for up to 72 hours after the server loses power.

The NiMH batteries in the battery pack are continuously recharged through a trickle-charging process

whenever the system power is on.

CAUTION:

To prevent a server malfunction or damage to the equipment, do not add or

remove the battery pack while an array capacity expansion, RAID level migration, or stripe

size migration is in progress.

CAUTION:

After the server is powered down, wait 15 seconds and then check the amber LED

before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds,
do not remove the cable from the cache module. The cache module is backing up data, and

data is lost if the cable is detached.

IMPORTANT:

The battery pack might have a low charge when installed. In this case, a POST

error message is displayed when the server is powered up, indicating that the battery pack is

temporarily disabled. No action is necessary on your part. The internal circuitry automatically

recharges the batteries and enables the battery pack. This process might take up to four hours.
During this time, the cache module functions properly, but without the performance advantage

of the battery pack.

NOTE:

The data protection and the time limit also apply if a power outage occurs. When

power is restored to the system, an initialization process writes the preserved data to the hard

drives.

To install the BBWC:

1.

Close all applications, and power down the server (on page

26

). This procedure flushes all data

from the cache.

2.

Remove the access panel ("

Removing and replacing the access panel

" on page

26

).

CAUTION:

Do not detach the cable that connects the battery pack to the cache module.

Detaching the cable causes any unsaved data in the cache module to be lost.