beautypg.com

Operations, Power up the server, Power down the server – HP ProLiant DL320s Server User Manual

Page 26: Removing and replacing the access panel

background image

Operations 26

Operations

In this section

Power up the server................................................................................................................................ 26

Power down the server............................................................................................................................ 26
Removing and replacing the access panel........................................................................................
......... 26

Removing the upper tray ......................................................................................................................... 27

Removing the PCI riser board assembly .................................................................................................... 28

Hot-plug fan operation............................................................................................................................ 29

Power up the server

To power up the server, press the Power On/Standby button.

Power down the server

WARNING:

To reduce the risk of personal injury, electric shock, or damage to the equipment,

remove the power cord to remove power from the server. The front panel Power On/Standby

button does not completely shut off system power. Portions of the power supply and some

internal circuitry remain active until AC power is removed.

IMPORTANT:

If installing a hot-plug device, it is not necessary to power down the server.

1.

Shut down the OS as directed by the OS documentation.

2.

Press the Power On/Standby button to place the server in standby mode. When the server enters
standby power mode, the system power LED changes to amber.

3.

Disconnect the power cords.

The system is now without power.

Removing and replacing the access panel

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the

internal system components to cool before touching them.

CAUTION:

Do not operate the server for long periods with the access panel open or removed.

Operating the server in this manner results in improper airflow and improper cooling that can

lead to thermal damage.

1.

Turn the captive screw to the unlocked position.

2.

Lift the latch.