beautypg.com

Lun configurations on the raid storage systems – HP XP P9500 Storage User Manual

Page 52

background image

Example 6 Using Raidscan to display TID and LUN for Fibre Channel devices

C:\>raidscan -pd hd6 -x drivescan hd6
Harddisk 6... Port[ 2] PhId[ 4] TId[ 3] Lun[ 5] [HITACHI ] [OPEN-3 ]
Port[CL1-J] Ser#[ 30053] LDEV#[ 14(0x00E)]
HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
RAID5[Group 1- 2] SSID = 0x0004
PORT# /ALPA/C,TID#,LU#.Num(LDEV#....)...P/S, Status,Fence,LDEV#,P-Seq#,P-LDEV#
CL1-J / e2/4, 29, 0.1(9).............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 1.1(10)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 2.1(11)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 3.1(12)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 4.1(13)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 5.1(14)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/4, 29, 6.1(15)............SMPL ---- ------ ----, ----- ----
Specified device is LDEV# 0014

In this case, the target ID indicated by the raidscan command must be used in the configuration
definition file. This can be accomplished using either of the following two methods:

Using default conversion table. Use the TID# and LU# indicated by the raidscan command in
the HORCM configuration definition file (TID=29 LUN=5 in

Example 6 “Using Raidscan to

display TID and LUN for Fibre Channel devices”

).

Changing default conversion table. Change the default conversion table using the
HORCMFCTBL environmental variable (see

Example 7 “Using HORCMFCTBL to change the

default Fibre conversion table”

) (TID=3 LUN=5 in

Example 7 “Using HORCMFCTBL to change

the default Fibre conversion table”

).

Example 7 Using HORCMFCTBL to change the default Fibre conversion table

C:\> set HORCMFCTBL=X

→ 'X' is fibre conversion table number.

C:\> horcmstart ...

→ Start of HORCM.

:
:
Result of "set HORCMFCTBL=X" command:
C:\>raidscan -pd hd6 -x drivescan hd6
Harddisk 6... Port[ 2] PhId[ 4] TId[ 3] Lun[ 5] [HITACHI ] [OPEN-3 ]
Port[CL1-J] Ser#[ 30053] LDEV#[ 14(0x00E)]
HORC = SMPL HOMRCF[MU#0 = SMPL MU#1 = SMPL MU#2 = SMPL]
RAID5[Group 1- 2] SSID = 0x0004
PORT# /ALPA/C,TID#,LU#.Num(LDEV#....)...P/S,Status,Fence,LDEV#,P-Seq#,P-LDEV#
CL1-J / e2/0, 3, 0.1(9).............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 1.1(10)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 2.1(11)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 3.1(12)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 4.1(13)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 5.1(14)............SMPL ---- ------ ----, ----- ----
CL1-J / e2/0, 3, 6.1(15)............SMPL ---- ------ ----, ----- ----
Specified device is LDEV# 0014

LUN configurations on the RAID storage systems

The RAID storage systems (XP1024/XP128 Disk Array and later) manage the LUN configuration
on a port through the LUN security as shown in the following figure.

52

Fibre-to-SCSI address conversion

This manual is related to the following products: