(2) Removing the environment variable.

$ DELETE/SYMBOL HORCC_MRCF
$ pairdisplay -g VG01 -fdc
Group PairVol(L/R) Device_File ,Seq#,LDEV#.P/S,Status,Fence, % ,P-LDEV# M
VG01 oradb1(L) DKA146 30009 146..SMPL ---- ------,----- ---- -
VG01 oradb1(R) DKA147 30009 147..SMPL ---- ------,----- ---- -
VG01 oradb2(L) DKA148 30009 148..SMPL ---- ------,----- ---- -
VG01 oradb2(R) DKA149 30009 149..SMPL ---- ------,----- ---- -
VG01 oradb3(L) DKA150 30009 150..SMPL ---- ------,----- ---- -
VG01 oradb3(R) DKA151 30009 151..SMPL ---- ------,----- ---- -
$

(3) Changing the default log directory.

$ HORCC_LOG := /horcm/horcm/TEST
$ pairdisplay
PAIRDISPLAY: requires '-x xxx' as argument
PAIRDISPLAY: [EX_REQARG] Required Arg list
Refer to the command log(SYS$POSIX_ROOT:[HORCM.HORCM.TEST]HORCC_VMS4.LOG (/HORCM
/HORCM/TEST/horcc_VMS4.log)) for details.

(4) Turning back to the default log directory.

$ DELETE/SYMBOL HORCC_LOG

(5) Specifying the device described in scandev.LIS.

$ define dev_file SYS$POSIX_ROOT:[etc]SCANDEV
$ type dev_file
DKA145-150
$
$ pipe type dev_file | inqraid -CLI
DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_ID
DKA145 CL1-H 30009 145 - - - - OPEN-9-CM
DKA146 CL1-H 30009 146 - s/S/ss 0004 5:01-11 OPEN-9
DKA147 CL1-H 30009 147 - s/P/ss 0004 5:01-11 OPEN-9
DKA148 CL1-H 30009 148 - s/S/ss 0004 5:01-11 OPEN-9
DKA149 CL1-H 30009 149 - s/P/ss 0004 5:01-11 OPEN-9
DKA150 CL1-H 30009 150 - s/S/ss 0004 5:01-11 OPEN-9

(6) Making the configuration file automatically.

You can omit steps from (3) to (6) on the startup procedures by using the mkconf command.

$ type dev_file
DKA145-150
$
$ pipe type dev_file | mkconf -g URA -i 9
starting HORCM inst 9
HORCM Shutdown inst 9 !!!
A CONFIG file was successfully completed.
HORCM inst 9 finished successfully.
starting HORCM inst 9
DEVICE_FILE Group PairVol PORT TARG LUN M SERIAL LDEV
DKA145 - - - - - - 30009 145
DKA146 URA URA_000 CL1-H 0 2 0 30009 146
DKA147 URA URA_001 CL1-H 0 3 0 30009 147
DKA148 URA URA_002 CL1-H 0 4 0 30009 148
DKA149 URA URA_003 CL1-H 0 5 0 30009 149
DKA150 URA URA_004 CL1-H 0 6 0 30009 150
HORCM Shutdown inst 9 !!!
Please check 'SYS$SYSROOT:[SYSMGR]HORCM9.CONF','SYS$SYSROOT:[SYSMGR.LOG9.CURLOG]
HORCM_*.LOG', and modify 'ip_address & service'.
HORCM inst 9 finished successfully.

$

SYS$SYSROOT:[SYSMGR]horcm9.conf (/sys$sysroot/sysmgr/horcm9.conf)

# Created by mkconf on Thu Mar 13 20:08:41
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
127.0.0.1 52323 1000 3000
HORCM_CMD
#dev_name dev_name dev_name
#UnitID 0 (Serial# 30009)
DKA145

26