Using cci with hitachi and other storage systems – HP XP P9500 Storage User Manual
Page 30
Using CCI with Hitachi and other storage systems
shows the related two controls between CCI and the RAID storage system type
(Hitachi or HP XP).
shows the relationship among the application, CCI, and
RAID storage system.
•
The following common HP API/CLI commands are rejected with EX_ERPERM(*1) by connectivity
of CCI with the RAID storage system:
horctakeover
paircurchk
paircreate
pairsplit
pairresync
pairvolchk
pairevtwait
pairdisplay
raidscan (except -find option only), raidar
raidvchkset
raidvchkdsp
raidvchkscan
•
The following HP API/CLI commands are rejected with EX_ERPERM(*2) on HITACHI storage
system even when both CCI and HP RAID Raid Manager are installed:
pairvolchk -s
pairdisplay -CLI
raidscan -CLI
paircreate -m noread for Continuous Access Synchronous
paircreate -m dif/inc for Business Copy
Table 11 Relationship between CCI and RAID storage system
XP API/CLI
Common API/CLI
RAID system
Installation order
CCI version
Cannot use (except
CLI)
Enable
Hitachi
CCI
CCI 01-08-03/00 or later
EX_ERPERM(*1)
HP
Enable
Hitachi
Install CCI after installing
RAID Manager
Enable
HP
Enable
Enable
HP
RAID Manager
HP RAID Manager
01.08.00 or later
EX_ERPERM(*2)
EX_ERPERM(*1)
Hitachi
Enable
Enable
HP
Install RAID Manager after
installing CCI
EX_ERPERM(*2)
Enable
Hitachi
30
Installation requirements