beautypg.com

Using cci with hitachi and other storage systems – HP XP P9500 Storage User Manual

Page 30

background image

Using CCI with Hitachi and other storage systems

Table 11 (page 30)

shows the related two controls between CCI and the RAID storage system type

(Hitachi or HP XP).

Figure 6 (page 31)

shows the relationship among the application, CCI, and

RAID storage system.

The following common HP API/CLI commands are rejected with EX_ERPERM(*1) by connectivity
of CCI with the RAID storage system:

horctakeover

paircurchk

paircreate

pairsplit

pairresync

pairvolchk

pairevtwait

pairdisplay

raidscan (except -find option only), raidar

raidvchkset

raidvchkdsp

raidvchkscan

The following HP API/CLI commands are rejected with EX_ERPERM(*2) on HITACHI storage
system even when both CCI and HP RAID Raid Manager are installed:

pairvolchk -s

pairdisplay -CLI

raidscan -CLI

paircreate -m noread for Continuous Access Synchronous

paircreate -m dif/inc for Business Copy

Table 11 Relationship between CCI and RAID storage system

XP API/CLI

Common API/CLI

RAID system

Installation order

CCI version

Cannot use (except
CLI)

Enable

Hitachi

CCI

CCI 01-08-03/00 or later

EX_ERPERM(*1)

HP

Enable

Hitachi

Install CCI after installing
RAID Manager

Enable

HP

Enable

Enable

HP

RAID Manager

HP RAID Manager
01.08.00 or later

EX_ERPERM(*2)

EX_ERPERM(*1)

Hitachi

Enable

Enable

HP

Install RAID Manager after
installing CCI

EX_ERPERM(*2)

Enable

Hitachi

30

Installation requirements

This manual is related to the following products: