beautypg.com

HP XP P9500 Storage User Manual

Page 37

background image

2.

Execute the following command:

$ PRODUCT INSTALL RM /source=Device:[PROGRAM.RM.OVMS]/LOG -

_$ /destination=SYS$POSIX_ROOT:[000000]
Device:[PROGRAM.RM.OVMS] where HITACH-ARMVMS-RM-V0122-2-1.PCSI exists

3.

Verify installation of the proper version using the raidqry command:

$ raidqry -h
Model: RAID-Manager/OpenVMS
Ver&Rev: 01-22-03/06
Usage: raidqry [options]

4.

Follow the requirements and restrictions in

“Porting notice for OpenVMS” (page 19)

.

Command execution by in-band and out-of-band methods

The methods of executing commands provided by RAID Manager can be classified into the in-band
and out-of-band methods.

In-band method. This method transfers a command from the client or the server to the command
device of the storage system via SVP and executing a RAID Manager operation instruction.

Out-of-band method. This method transfers a command from the client or the server to the
virtual command device in the SVP via LAN, assigning a RAID Manager operation instruction
to the DKC, and executing it.

For executing a command by the in-band and out-of-band methods, a command device or a virtual
command device is set in a configuration definition file as shown in the following figure, an IP
address of the SVP is specified in the configuration definition file.

The following figure shows a system configuration example and a setting example of a command
device and a virtual command device by the in-band and out-of-band methods.

Command execution by in-band and out-of-band methods

37