9 troubleshooting, When the tape blade does not power up, Troubleshooting tape blade operation – HP StoreEver LTO Ultrium Tape Blades User Manual
Page 59
9 Troubleshooting
Read this chapter for information about:
• When the Tape Blade does not power up
• Management and Diagnostic tools
•
NOTE:
For information about troubleshooting using Tape Blade and tape drive LEDs, see “
When the Tape Blade does not power up
If the Tape Blade does not start, use the following table to help resolve the problem:
Table 6 Troubleshooting Tape Blade operation
Possible solutions
Possible reasons
Verify that the Tape Blade is installed adjacent to the partner
server blade. See “
Installing an HP StorageWorks Tape
•
The Tape Blade is not installed in the
correct location for the partner server
blade.
Restart the server blade and verify that the Tape Blade front panel
system health LED changes from flashing red to solid green.
•
The partner server blade was not restar-
ted after the Tape Blade was installed.
1.
Power down the partner server blade.
2.
Reseat the Tape Blade in the device bay.
3.
Restart the server blade and verify that the Tape Blade front
panel system health LED changes from flashing red to solid
green.
•
The Tape Blade is not properly seated
in the device bay.
Purchase and install the required card, option kit part number:
431643-B21.
•
No mezzanine pass-thru card installed
with a full-height server
Firmware version 1.3 or later is required when installing in a
c7000 enclosure. In a c3000 enclosure all versions of the firm-
ware support the HP StorageWorks Tape Blade. For the best reli-
ability, performance and new features update to the most recent
version of the firmware.
•
The c-Class enclosure firmware is at the
wrong version
Use the Onboard Administrator to verify that sufficient power and
cooling are available.
•
There is insufficient power or cooling
Tape Blade
59