Flashing previous firmware versions – HP Lights-Out 100 Remote Management User Manual
Page 14

Configuration 14
takes several minutes. After the firmware upgrade process is complete, verify that the new version of
the firmware is active.
If the firmware upgrade process fails after sufficient time (at least 5 minutes), reboot the server, and
verify that the previous version of the firmware is still active. Always reboot the server before retrying
the firmware upgrade process.
After installing the firmware, the IP address of the server might reset to the default value. You must
locally reset the IP address to the desired address.
NOTE:
After using the
load
command LO 100 will reset ending your CLP interface session.
You must reconnect to the CLP interface.
NOTE:
When you use the CLP
load
command with TFTPD32, HP recommends using a 30-
second timeout and 6 retries.
Flashing previous firmware versions
When an HP Lights-Out 100c Remote Management Card is installed in a ProLiant DL180 server and you
want to flash the LO 100 back to an earlier version, you must enter the CLP command
oemhp i 20 20
c0 18 00 04 04 e0(select the most recently programmed)
in the
map1
directory to
ensure that the previous version is reactivated.