beautypg.com

HP Neoview Release 2.5 Software User Manual

Page 16

background image

Table 2-2 Neoview VTS System Status Field Information for 7.04.02

Description

Field

Box Title

Box

The host name of the Neoview VTS server.

Host

System

[1]

The current date and time.

Time

The version of software (including patches) installed on the Neoview VTS
server.

Version

Software

[2]

The date on which the installed Neoview VTS software was created.

Created

The active status of EMS, which enables the Neoview VTS to send messages
and errors to the Neoview platform.

EMS

Services

1

[3]

The active status of the Neoview VTS.

VTS

The active status of automated Removable Media Disaster Recovery (RMDR),
which integrates Neoview VTS with enterprise backup applications. The
possible status values are:

Stopped – RMDR is not enabled and not running.
Inactive – RMDR is enabled and not running.
Waiting – RMDR is running and enabled. RMDR remains in this state until
RMDR runs, RMDR is disabled, or RMDR is stopped.
Running – A migration is in progress.
Disabled – RMDR is disabled but still running. This is a transitory state
while RMDR completes an orderly shutdown.

RMDR

The name of a vault within the Neoview VTS system. Click the vault name
to list all of the pools in the vault and the amount of space consumed by
each pool.

Vault/Pool

Free Space

[4]

For a vault, the amount of space used in the vault, including the percentage
of the vault used. For a pool, the amount of space used by the pool.

Usage

The amount of space available for storage.

Total Size

The name of the virtual tape device.

Device

Connections

[5]

The transfer rate for the virtual tape device.

Kb/sec

The compression ratio for data traveling between the Neoview platform and
the Neoview VTS.

C/Ratio

The name of the cartridge mounted on the virtual tape device. To view the
last command that was sent to the tape drive, position the cursor over the
icon in this column.

Cartridge

1

If a service is enabled, it is listed in the Services section of the page.

16

Viewing the VTS System Status and VTS RMDR Service Window