HP Integrity NonStop H-Series User Manual
Page 58

Troubleshooting
9840 (CT9840FC-3) Installation and User’s Guide for the NonStop S-Series Enclosure— 524959-003
A- 4
Operator Panel Messages
CodUpFail1
Unable to read tape.
Unable to read position on tape.
Unable to read image on tape.
Try another tape.
CodUpFail2
EEPROM bad.
Before running an IPL, try
another tape.
Perform an IPL. If problem
persists, replace drive.
CodUpFail3
Unreadable tape format.
Reclaim as data tape, re-create
code tape.
Retry operation.
Try another tape.
If persistent, go to “Force a
Diagnostic Dump (Reset Drive)”.
CodUpFail4
Not a code updated tape.
Retry with correct tape.
If persistent, go to “Force a
Diagnostic Dump (Reset Drive)”.
DatCrFail1
Unable to create (format) a data
tape.
Ensure tape is write-enabled.
Try another drive.
If persistent, go to “Force a
Diagnostic Dump (Reset Drive)”.
DmpCrFail1
Unable to create (format) a dump
tape.
Ensure tape is write-enabled.
Try another tape.
Try another drive.
If persistent, go to “Force a
Diagnostic Dump (Reset Drive)”.
DmpCrFail2
Unreadable tape format.
Reclaim as data tape.
Retry operation.
Try another tape.
If persistent, go to “Force a
Diagnostic Dump (Reset Drive)”.
DumpToHost
Dump or event log is being
transferred to server. Operation
panel switches are locked.
No user action is necessary.
DmpWrFail1
Unable to write dump to tape.
Unable to position on tape.
Try another tape. Ensure tape is
formatted for dump.
DmpWrFail2
No dump to process.
Force a dump. Go to “Force a
Diagnostic Dump (Reset Drive).”
Table A-1. Operator Panel Displays