Only IPv4 addresses are supported in this release.

Command line syntax

CLI input is case-insensitive except when otherwise noted. The general CLI syntax is as follows:

vcsu -a

Parameters are extensions that provide extra information required for the execution of a particular command.

Whether or not a parameter is required depends on the specific action being executed.
For example, the version command includes parameters for IP address, username, password, and bay

location. The syntax is as follows:

vcsu -a version -i -u -p [-b ]

NOTE:

When entering a username from a Linux command shell with the domain\username

format, use quotation marks around the username ("domain\username") so it is not expanded

by the Linux shell.

To display a single module and its current firmware version, enter the following:

vcsu -a version -i 192.168.1.100 -u Administrator -p password -b 1

Usage

To install and run the HP BladeSystem c-Class Virtual Connect Support Utility:

1.

Install the application on the client system by running the MSI file.

2.

After the program is installed, click Start>Programs>Hewlett-Packard>Virtual Connect Support Utility to
start a console.

o

To start the Virtual Connect Support Utility in interactive mode, enter vcsu.

o

To display the top-level help and available options, enter vcsu -a.

o

To display version syntax and available options, enter vcsu -a version.

o

To display report syntax and available options, enter vcsu -a report.

o

To display update syntax and available options, enter vcsu -a update.

o

To display discover syntax and available options, enter vcsu -a discover.

o

To display collect syntax and available options, enter vcsu -a collect.

o

To display configbackup syntax and available options, enter vcsu -a configbackup.

o

To display supportdump syntax and available options, enter vcsu -a supportdump.

o

To display healthcheck syntax and available options, enter vcsu -a healthcheck.

o

To display packageinfo syntax and available options, enter vcsu -a packageinfo.

o

To display resetvcm syntax and available options, enter vcsu -a resetvcm.

3.

Download a valid Virtual Connect firmware package file from the HP website

(

http://www.hp.com/go/bladesystemupdates

), and then save it to your local file system.

4.

Enter the version command to display all of the modules in the enclosure and ensure that the required

connectivity exists between the utility and the remote enclosure.
Non-VC modules are shown as “Unknown or unsupported module.” Version information appears for