Resetvcm, Supportdump – HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 14
Commands 14
vcsu -a report -i 192.168.1.100 -u Administrator -p password -1 VCpackage
-b 2
resetvcm
Log into the specified interconnect bay and restart the Virtual Connect Manager service. This is the same
process as the menu option "Reset VC Manager" from the Virtual Connect user interface.
Item
Description
Syntax
vcsu -a resetvcm -i
Parameters:
IP
IPv4 address of the active OA in the enclosure*
USER
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length
is 1 character. Maximum length is 40 characters.**
PWD
Password of the OA user. Minimum length is 3 characters. Maximum length is 40
characters.**
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
local and all remote enclosures in the Virtual Connect domain.
Example
Reset a single module in an enclosure:
vcsu -a resetvcm -i 192.168.0.100 -u Administrator -p password -b 1
supportdump
Log into VC Manager using the supplied credentials and access Virtual Connect to request a support
information (debug dump) download. VCSU saves that file in the current directory as the file name supplied
by Virtual Connect. A functioning VC Manager domain is required for this action.
Item
Description
Syntax
vcsu -a supportdump -i PASS> -l Parameters: IP IPv4 address of the active OA in the enclosure* USER Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length is 1 character. Maximum length is 40 characters.** PWD Password of the OA user. Minimum length is 3 characters. Maximum length is 40 characters.** VCM USER Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual VCM PASS Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31 characters. LOCATION Full path, including file name, to save the support dump file. If not provided, VCSU saves the *In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure. local and all remote enclosures in the Virtual Connect domain. Example
Connect domain. Minimum length is 1 character. Maximum length is 31 characters.
support dump file to the file name that VCM provides and downloads it to the current directory.
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem