HP Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem User Manual
Page 16
Commands 16
Item
Description
to activate (reboot) modules.
-of
Optional. Specifies VC-FC module activation order. The following activation order methods
are supported:
•
parallel—All modules are activated at the same time.
•
odd-even—All modules in odd-numbered bays are activated first, and then modules in
even-numbered bays are activated.
•
serial—(Default) Modules are activated one at a time, starting with the highest
numbered bay.
•
manual—Modules are updated but not activated. Use the OA GUI to activate (reboot)
modules.
-we
Optional. Specifies the amount of time, in minutes, to wait between activating or rebooting
VC-Enet modules. This command is required for some MPIO/teaming software on the server
blades in the enclosure. The default is 0, or no delay. HP recommends a minimum of 5
minutes.
-wf
Optional. Specifies the amount of time, in minutes, to wait between activating or rebooting
VC-FC modules. This command is required for some MPIO/teaming software on the server
blades in the enclosure. The default is 0, or no delay. HP recommends a minimum of 5
minutes.
-cp
Optional. Password for the configuration backup file. Supported in VCM firmware versions
3.00 and higher. The default is no password.
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
local and all remote enclosures in the Virtual Connect domain.
Examples
Update multiple modules in an enclosure imported into a VC domain:
vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -vcp
vcPass -l C:\images\vcfw-120.bin
Update a single module in an enclosure not imported into a VC domain:
vcsu -a update -i 192.168.1.100 -u Administrator -p password -l vcfw121.bin
-b 3
Update a single module in an enclosure managed by the VC domain:
vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -vcp
vcPass -l C:\images\vcfw-120.bin -b 3
Perform an update and specify an activation ordering method:
vcsu -a update -i 192.168.1.100 -u Administrator -p password -vcu John -vcp
vcPass -l C:\images\vcfw-120.bin -oe serial -of parallel
Perform an update using a firmware image from a web server address:
vcsu –a update –i 192.168.1.100 –u Administrator –p password –l
http://www.myserver.com/vcfw-120.bin
Perform an update using a firmware image from an FTP server on the network:
vcsu –a update –i 192.168.1.100 –u Administrator –p password –l
ftp://user:[email protected]/vcfw-120.bin
Perform an update of the same firmware version on a degraded module:
vcsu -a update -i 192.168.1.100 -u Administrator -p password -l
C:\images\vcfc-120.bin -f version,health
- Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem