beautypg.com

HP NC373F PCI-E Multifunction 1000SX Gigabit Server Adapter User Manual

Page 12

background image

Installation and configuration 12

# Hard coded Target IP .. No DNS support
#
TargetName=iqn.2003-05.com.hp1510i:Target01
TargetIP=10.10.10.13
#
# local name the iSCSI client will present to the Target
# and local IP settings. No DNS or DHCP support
#
InitiatorName=iqn.client01
InitiatorIP=10.10.10.02
InitiatorNetmask=255.255.255.0
InitiatorRoute=10.10.10.1
TargetPort=3260
## Locally Admin Address (MAC address) and VLAN (Enabled/Disabled)
#
LAA=000000000000
VLAN=Disabled
## LUN Mapping. This should match what the target LUN offers.
#
LUN=0
## Make this persistent BIOS int 13 IPL routine. Replaces Embedded HD

C:\ (if present).
#.
#Exceptions: Platforms with updated System ROM versions that support

#network adapters in the RBSU "Boot controller order" should have

#ForceBoot=False
#
ForceBoot=True
## Enable Checksum (digest) of Data header or Checksum Data fields

within a PDU. Value must match the target setting, if the parameters

don't match on the end points, iSCSI won't establish a session.
#
DataDigest=False
HeaderDigest=False
## Account Login information
# . The AuthMethod values are: None, CHAP, and (TwoWay) MutualCHAP,
#
AuthMethod=None
##
# If AuthMethod is None, These are ignored.
CHAPUsername=iqn.1991-05.com.microsoft:comfort.txn.cpqcorp.net
CHAPSecret=Some12day123
CHAPMSecret=BetterThanThat

3.

Write the boot path to the target server. The boot path configuration file may be written to the target
server with the ev DOS utility or written using the ibootcfg utility.

o

To write the boot path using the ev DOS utility, boot to DOS and change directories to the ev
DOS utility. The ev DOS utility is packaged with the HP iSCSI boot feature.