Examples of raid manager configurations – HP XP RAID Manager Software User Manual
Page 66
Examples of RAID Manager configurations
The following examples show RAID Manager configurations, the configuration definition file(s) for
each configuration, and examples of RAID Manager command use for each configuration.
The command device is defined using the system raw device name (character-type device file
name). For example, the command devices for the following figure would be:
•
HP-UX:
HORCM_CMD of HOSTA = /dev/rdsk/c0t0d1 HORCM_CMD of HOSTB =
/dev/rdsk/c1t0d1
•
Solaris:
HORCM_CMD of HOSTA = /dev/rdsk/c0t0d1s2 HORCM_CMD of HOSTB =
/dev/rdsk/c1t0d1s2
For Solaris operations with RAID Manager version 01-09-03/04 and higher, the command
device does not need to be labeled during format command.
•
AIX:
HORCM_CMD of HOSTA = /dev/rhdiskXX HORCM_CMD of HOSTB = /dev/rhdiskXX
where XX = device number assigned by AIX
•
Tru64 UNIX:
HORCM_CMD of HOSTA = /dev/rrzbXXc HORCM_CMD of HOSTB = /dev/rrzbXXc
where XX = device number assigned by Tru64 UNIX
•
DYNIX/ptx™:
HORCM_CMD of HORCMINST0 = /dev/rdsk/sdXX
HORCM_CMD of HORCMINST1 = /dev/rdsk/sdXX
where XX = device number assigned by DYNIX/ptx™
•
Windows 2000/2003/2008:
HORCM_CMD of HOSTA = \\.\CMD-Ser#-ldev#-Port# HORCM_CMD of HOSTB = \\.\CMD-Ser#-ldev#-Port#
•
Windows NT:
HORCM_CMD of HORCMINST0 = \\.\CMD-Ser#-ldev#-Port#
HORCM_CMD of HORCMINST1 = \\.\CMD-Ser#-ldev#-Port#
•
Linux, z/Linux:
HORCM_CMD of HOSTA = /dev/sdX HORCM_CMD of HOSTB = /dev/sdX
where X = device number assigned by Linux, z/Linux
•
IRIX:
HORCM_CMD for HOSTA/dev/rdsk/dks0d0l1vol or
/dev/rdsk/node_wwn/lun1vol/c0p0
HORCM_CMD for HOSTB/dev/rdsk/dks1d0l1vol or
/dev/rdsk/node_wwn/lun1vol/c1p0
Figure 18 Continuous Access Synchronous Remote Configuration Example
66
Sample configuration definition files