beautypg.com

HP XP RAID Manager Software User Manual

Page 37

background image

2.

Execute the following command:

$ PRODUCT INSTALL RM /source=Device:[PROGRAM.RM.OVMS]/LOG -

_$ /destination=SYS$POSIX_ROOT:[000000]
Device:[PROGRAM.RM.OVMS] where HITACH-ARMVMS-RM-V0122-2-1.PCSI exists

3.

Verify installation of the proper version using the raidqry command:

$ raidqry -h
Model: RAID-Manager/OpenVMS
Ver&Rev: 01-22-03/06
Usage: raidqry [options]

4.

Follow the requirements and restrictions in

“Porting notice for OpenVMS” (page 19)

.

Command execution by in-band and out-of-band operations

RAID Manager operations can be performed using either the in-band method (XP24000/XP20000
Disk Array and earlier) or the out-of-band method (new on P9500).

In-band method. This method transfers a command from the client or the server to the command
device of the storage system via SVP and executing a RAID Manager operation instruction.

Out-of-band method. This method transfers a command from the client or the server to the
virtual command device in the SVP via LAN, assigning a RAID Manager operation instruction
to the DKC, and executing it.

The following figure shows a system configuration example and a setting example of a command
device and a virtual command device by the in-band and out-of-band methods.

Figure 7 System configuration example and setting example of command device and virtual
command device by in-band and out-of-band methods

Command execution by in-band and out-of-band operations

37