Example 9 Configuration File Example – UNIX-Based Servers

HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
HST1 horcm 1000 3000
HORCM_CMD
#unitID 0... (seq#30014)
#dev_name dev_name dev_name
/dev/rdsk/c0t0d0
#unitID 1... (seq#30015)
#dev_name dev_name dev_name
/dev/rdsk/c1t0d0
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
oradb oradb1 CL1-A 3 1 0
oradb oradb2 CL1-A 3 1 1
oralog oralog1 CL1-A 5 0
oralog oralog2 CL1-A1 5 0
oralog oralog3 CL1-A1 5 1
oralog oralog4 CL1-A1 5 1 h1
HORCM_INST
#dev_group ip_address service
oradb HST2 horcm
oradb HST3 horcm
oralog HST3 horcm

Figure 12 Configuration File Example – Windows Servers

The configuration file sets the following parameters:

(1) HORCM_MON

The monitor parameter (HORCM_MON) defines the following values:

Ip_address: The network address (IPv4 or IPv6) of the local host. When HORCM has two or
more network addresses on different subnets or MPE/iX, enter NONE for IPv4 or NONE6 for
IPv6 here.

Service: Specifies the UDP port name assigned to the HORCM communication path, which is
registered in "/etc/services" ("\WINNT\system32\drivers\etc\services" in Windows,
"SYS$SYSROOT:[000000.TCPIP$ETC]SERVICES.DAT" in OpenVMS). If a port number is
specified instead of a port name, the port number is used.

Sample configuration definition files

57