maintenance guide

52

Overheat

Insuffi

cient

circulation

Water pressure

Bleed heat exchanger

Pump operation

CH return fi lter for blockages

Circulation around boiler (blockages)

ntc temperature sensors

Insuffi

cient water

(request fi lling)

Water pressure gauge for correct pressure

Check for waterleaks on the entire system

CH Flow temp.

probe circuit open/

short circuit

Check connections and wiring to temp

sensors

CH Flow temp.

probe circuit open/

short circuit

Resistance values of temp sensors

Heating delivery

probe problem

Details in maintenance guide in installation

manual

Floor thermostat

contact open

Check terminals TA2 for presence of link

wire

EEPROM Error

Check the EEPROM connection onto the

pcb

Communication

error

Check connection and wiring onto all

devices, main and display pcb

Main PCB error

Too many (>5)

resets in 5 minutes

Identify reason for lockout from table and

check for relevant faults

No Flame detected

Insuffi

cient working gas pressure

1st Ignition failed

Spark electrode/wiring connectors

2nd Ignition failed

Ignition electrode/wiring connectors

Flame cut-off

Spark generator/wiring connectors

Check fl ue system for correct assembly/

termination

Check earth

Gas valve

CO2 settings

Soft light rate

Flame detected

with gas valve

closed

Ignition electrode/wiring connectors

Ignition electrode wiring connection onto

main pcb

Flame lift

Insuffi

cient working gas pressure

Check fl ue system for correct assembly/

termination

CO2 settings

Thermofuse open

Check wiring and connections to

thermofuse

Check integriry of main heat exchanger

Fan speed error

Check fan

Check wiring connections from fan to pcb

Fault fi nding