maintenance guide

51

Annual Maintenance

Plate heat exchanger

Maintenance Interval: As
necessary
How: To measure specifi -
cation of DHW perfor-
mance.

By-pass & Safety valve

Maintenance Interval:
Annually
How: Visual inspection /
Clean as necessary

Central heating fi lter

Maintenance Interval:
Annually
How: Visual inspection /
Clean as necessary

Flow switch operation

Maintenance Interval:
Annually

How: Visual inspection /
Clean as necessary
/ Check fl ow rate

Expansion vessel

Maintenance Interval:
Annually
How: Check air pressu-
re is at 1 bar (System
drained)

Ignition & detection
electrodes

Maintenance Interval:
Annually
How: Visual inspection /
Clean as necessary / Di-
stance from the burner /
Ionisation current more
than 1 μA

Burner

Maintenance Interval:
Annually
How: Visual inspection /
Clean as necessary

Fan

Maintenance Interval:
Annually
How : Visual inspection /
Clean as necessary

Primary Heat
exchanger

Maintenance Interval:
Annually
How : Visual inspection /
Clean as necessary

Condensate trap

Maintenance Interval:
Annually
or after cleaning primary
heat exchanger

How: Visual inspection /
Clean as necessary /
Add water before
replacing

Pump

Maintenance Interval:
At the fi rst ignition and
annually

How: Check that the
AAV is open /
Visual inspection / Clean
as necessary