beautypg.com

Maintenance guide – Ariston E-COMBI 24 30 38 User Manual

Page 44

background image

maintenance guide

44

Tools

Time

5 min

1

NTC1 NTC2

NTC1 : Black wires

NTC2 : Grey wires

Unplug the electrical connectors

Remove the clip and the temperature sensor

TEMPERATURE (°C)

RESISTANCE (kOmh)

0

27

10

17

20

12

25

10

30

8

40

5

50

4

60

3

70

2

80

1,5

Tools

Time

5 min

1

Drain boiler (see 3.3). Remove the second

clip and pull the assembly toward you

Push on the by-pass to disengage it

By-Pass Assembly

Temperature Sensor