maintenance guide
44
Tools
Time
5 min
1
NTC1 NTC2
NTC1 : Black wires
NTC2 : Grey wires
Unplug the electrical connectors
Remove the clip and the temperature sensor
TEMPERATURE (°C)
RESISTANCE (kOmh)
0
27
10
17
20
12
25
10
30
8
40
5
50
4
60
3
70
2
80
1,5
Tools
Time
5 min
1
Drain boiler (see 3.3). Remove the second
clip and pull the assembly toward you
Push on the by-pass to disengage it
By-Pass Assembly
Temperature Sensor