Tools

Time

5 min

1

Remove the clip and lift the manual air vent from the exchanger

Tools

Time

20 min

1

Drain boiler (see 3.3). Remove the four clips
and disconnect the two pipes between the
exchanger and pump and between the ex-
changer and left hand hydraulic block

Isolate the gas supply. Remove the four
screws and disconnect the gas pipe from
the gas valve

Remove the four screws to free the heat ex-
changer

2

Pull the heat exchanger towards you

Remove the clip and lift the manual air vent Twist the thermal fuse to remove

Manual Air vent