Installation – Ariston E-COMBI 24 30 38 User Manual

Page 23

background image

23

installation

Table of fl ue gas exhaust duct lengths

Type

Maximum Extension Exhaust-air (m)

Diameter of pipe

(mm)

E-COMBI 24

E-SYSTEM 24

E-COMBI 30

E-SYSTEM 30

E-COMBI 38

MIN

MAX

MIN

MAX

MIN

MAX

Coaxial System

C13
C33

0,5

12

0,5

12

0,5

6

ø 60/100

C13
C33

0,5

36

0,5

36

0,5

18

ø 80/125

Twin-pipe System

C13
C33

S1 = S2

S1 = S2

S1 = S2

ø 80/80

0,5/0,5

36/36

0,5/0,5

48/48

0,5/0,5

18/18

C53

1 + S2

1 + S2

1 + S2

ø 80/80

1/0,5

1/83

1/0,5

1/70

1/0,5

1/42

S1 = Air intake S2 = Flue gas exhaust

S1 = S2 - Air intake and fl ue gas exhaust equal lengths
S1 + S2 - Air intake and fl ue gas exhaust unequal lengths

Combustion air intake from outside

C13

Flue gas exhaust and air suction
duct through external wall in
the same range of pressure

C33

Flue gas exhaust andair suction
duct from outsidewithroof
terminalin the same range of
pressure

C53

Flue gas exhaust leading
outside and air suction duct
through external wall not in the
same range of pressure

Type of air suction/fl ue gas exhaust ducting