Supplying Power to the Unit

The TRACER MPS can operate from a supply between 21 and 63 Volts DC, with either polarity referenced to ground, and consumes
3 Watts nominal, 20 Watts peak (during relay switching). Current required (in Amps) is determined by dividing the power consumed (in
Watts) by the applied voltage (in Volts). As an example at 48 Volts, the TRACER MPS would draw approximately 0.417 Amps peak (20
Watts / 48 Volts).

9

Pinouts

MAIN/STANDBY T1A/T1B I

NTERFACES

(RJ-45)

Pin

Name

Description

1

R

TRANSMIT DATA (RING)

2

T

TRANSMIT DATA (TIP)

3, 6-8

UNUSED

4

R1

RECEIVE DATA (RING)

5

T1

RECEIVE DATA (TIP)

RS-232 C

ONSOLE

I

NTERFACE

(DB-25)

Pin

Name

Description

1, 8-25

UNUSED

2

TXD

TRANSMIT DATA

3

RXD

RECEIVE DATA

4

RTS

REQUEST TO SEND

5

CTS

CLEAR TO SEND

6

DSR

DATA SET READY

7

GROUND

TERMINAL GROUND