7

6b

Connecting the Antenna Interfaces (TRACER 4103 and 4203 Systems)

1. Connect the Antenna interface (N-Type connector) of the MAIN TRACER 4103/4203 (labeled 1 below) to the MAIN RF interface (SMA

connector) of the TRACER MPS (labeled 2 below) using a male N-Type to male SMA cable.

2. Repeat Step 1 to connect the Antenna interface (N-Type connector) of the STANDBY TRACER 4103/4203 to the STANDBY RF inter-

face (SMA connector) of the TRACER MPS (labeled 3 below).

T

R

A

C

E

R

MAIN

STANDBY

OUT

NO COM NC

MN COM SB

IN

ALARMS

DC POWER

RF

ANTENNA

TO DTE RS-232

MONITOR

T1B

T1A

MAIN

TRACER

STANDBY

TRACER

MONITOR

POWER

MODULE

USE COPPER

CONDUCTORS ONLY

OUT

IN

IN

OUT

B

A

B

A

MAIN

STAND

BY

T1B

T1A

MAIN UNIT Antenna Interface

1

2

3

TRACER MPS STANDBY
Antenna Interface

4

MAIN UNIT Antenna Interface

TRACER MPS MAIN
Antenna Interface

3. Connect the TRACER MPS Antenna interface (N-Type connector, labeled 4 above) to the customer provided antenna using antenna

feedline cabling. Refer to the appropriate TRACER User Manual for a detailed discussion on link planning, antenna loss/gain, and