HP Matrix Operating Environment Software User Manual
Page 62
After ESA is installed as part of Insight Dynamics, the WSDL is available at http://
localhost:52000/esa/services/serverservice?wsdl
. The XSD file
(esa-server-model-1.0.xsd) can be found at C:\Program Files\HP\Virtual Server
Environment\esa\etc\xsd\esa-server-model-1.0.xsd
.
For more information about HP Operations Orchestration and ESA, see the Server and Storage
Workflows for HP Insight Dynamics white paper at
.
ESA configuration is stored in a property file called esa.properties, included in the C:\
Program Files\HP\Virtual Server Environment\conf
directory. The parameters that
you can configure include:
•
Operations Orchestration system IP address
•
Operations Orchestration username and credentials
•
Operations Orchestration replytoURI
This is the URI to which OO posts the results of the workflow. This value is passed to the
workflow as an input parameter.
•
Workflow path
For example, in the workflow path ESA/Get Server Info, ESA is the folder name and
Get Server Info
is the flow name.
Following is an example ESA properties file.
#
### WorkFlow Details
#
#esa.oo.*.path - Indicates the path of the work flow relative to Library folder in OO.
#Valid Types: ASYNCHRONOUS, SYNCHRONOUS
#Valid Status: ENABLED, DISABLED)
#timeout value in milliseconds.
#
#SERVER WorkFlows
esa.oo.get.server.info.flow.path = Hewlett-Packard/ESA/Server/Flows/Get Server Info
esa.oo.get.server.info.flow.type = ASYNCHRONOUS
esa.oo.get.server.info.flow.status = ENABLED
esa.oo.get.server.info.flow.timeout = 60000
#
###OO - Configuration
#
#esa.oo.communication.protocol - Protocol for communicating with the OO server.
#esa.oo.admin.username - Username of OO server.
#esa.oo.admin.password - Password of OO server.
#esa.oo.host - indicates the ip address of the OO server.
#esa.oo.port - Port number of the OO Server
#
#esa.oo.service.ws.path - Path to the OO service.
#esa.oo.timeout.workflow – Presently not used.
#esa.oo.retry.count – Presently not used.
#esa.oo.syncpolling - This property is only for synchronous calls, and can be ignored as of now.
#esa.oo.san.replytoURI - URI to which OO should call back for storage workflows.
#esa.oo.server.replytoURI - URI to which OO should call back for server workflows.
#
esa.oo.communication.protocol=https
esa.oo.admin.username=Admin
esa.oo.admin.password=password
esa.oo.host=xx.xx.xx.xx
esa.oo.port=16443
esa.oo.service.ws.path=/PAS/services/WSCentralService
esa.oo.timeout.workflow=30
esa.oo.retry.count=3
esa.oo.syncpolling=100
esa.oo.esacertificate.presentIn.OO=FALSE
esa.oo.san.replytoURI=http://xx.xx.xx.xx:52000/esa/services/oostorageservice?wsdl
esa.oo.server.replytoURI=http://xx.xx.xx.xx:52000/esa/services/ooserverservice?wsdl
62
Managing logical servers