HP ProLiant DL380 Server User Manual
Page 16

c.
Edit the DEPLOYSERVER.CMD file for your specific environment.
NOTE:
The IFHW and HWQUERY utilities can be used to assist in customizing the
DEPLOYSERVER.CMD script for your environment. For more information about these
utilities, see
.
The DEPLOYSERVER.CMD file is similar to the following:
rem @echo off
cls
echo [ SCRIPT FOR REMOTE INSTALL OF W2K3 ON TYPICAL SERVER ]
REM pause
echo Retrieving State Information...
%Tools%\System\statemgr /r phase
if errorlevel 3 goto State3
if errorlevel 2 goto State2
if errorlevel 1 goto State1
if errorlevel 0 goto State0
:State0
REM *** Configure the target server hardware by reading the
REM *** configuration information in the script file
echo Running Configuration Replication Utility...
%Tools%\System\conrep -l -f%GlobalData%\HardwareSettings\hwconfig.xml -x%Tools%\System\conrep.xml
echo Setting State Information...
%Tools%\System\statemgr /w Phase 1
:State1
REM===============================================================
REM *** Configure the array controllers by reading the
REM *** configuration information in the script file and stamping
REM *** it onto the array controllers of the target server
REM===============================================================
echo Configuring the Array Controllers...
%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 5i Controller"
if errorlevel 1 GOTO NEXT1
%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r0.ini
GOTO NEXT5
:NEXT1
%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 6i Controller"
if errorlevel 1 GOTO NEXT2
%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r1.ini
GOTO NEXT5
:NEXT2
%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 5312"
if errorlevel 1 GOTO NEXT3
%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r1.ini
GOTO NEXT5
:NEXT3
%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 640X Controller"
if errorlevel 1 GOTO NEXT4
%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r5.ini
GOTO NEXT5
16
Advanced topics
- ProLiant BL465c Server Blade ProLiant BL2x220c G7 Server-Blade ProLiant DL120 G7 Server ProLiant SL250s Gen8 Server ProLiant BL680c G5 Server-Blade ProLiant DL320s Server ProLiant SL230s Gen8 Server ProLiant BL2x220c G6 Server-Blade ProLiant BL480c Server-Blade ProLiant DL385 Server ProLiant BL2x220c G5 Server-Blade Intelligent Provisioning ProLiant BL490c G6 Server-Blade ProLiant BL620c G7 Server-Blade ProLiant DL365 G5 Server ProLiant ML330 G6 Server ProLiant BL490c G7 Server-Blade ProLiant DL360p Gen8 Server ProLiant SL335s G7 Server ProLiant DL320 Server ProLiant BL495c G5 Server-Blade ProLiant BL460c Gen8 Server Blade ProLiant DL360 Server ProLiant BL280c G6 Server-Blade ProLiant ML350p Gen8 Server ProLiant DL585 Server ProLiant ML370 Server ProLiant DL380p Gen8 Server ProLiant SL390s G7 Server ProLiant BL460c Server-Blade ProLiant ML310 G5 Server ProLiant BL680c G7 Server-Blade ProLiant BL260c G5 Server-Blade ProLiant BL495c G6 Server-Blade ProLiant DL160 Gen8 Server ProLiant ML350 Server ProLiant DL370 G6 Server ProLiant BL685c Server-Blade ProLiant DL785 G6 Server ProLiant DL785 G5 Server