Avaya M770 Hub Components

Avaya M770 User’s Guide

13

M-SPV/M-SPX Front Panel

Figure 3.3M-SPX Front Panel

New M-SPX Functionality

IDS Switch (M-SPX only)

The M-SPX front-panel Inter-Domain Switch (IDS) enables you to
combine the two Avaya M770 X-Domains, effectively doubling the
available port count. Set the switch ON or OFF as required.

Caution:

When installing two M-SPX modules, the IDS switch must be

set to the same position on both modules.

Sideband Port SB2-ETH

Two RJ-45 Sideband ports, SB1-ETH and SB2-ETH, on the Avaya M770
hub front panel are supported by the M-SPX (see Figure 3.1). The
M-SPV supports only the SB1-ETH port.

Resetting the M-SPV/M-SPX

Each M-SPV/M-SPX can be reset individually via a reset button on the Control
Panel (see page 10) or using the reset button on the M-SPV/M-SPX module itself.
Resetting the M-SPV/M-SPX does not reset the entire hub (for details on resetting
the hub, see page 10).

Table 3.4

M-SPV/M-SPX Front Panel LEDs

LED Name

Represents

State

Function

OPR

Module
Operationa
l Status

On

Module is
functioning
normally

Blinkin
g

Module is
faulty

MAIN

Main/
Backup

On

Main/active
M-SPV/M-SPX

Off

Backup/
dormant
M-SPV/M-SPX