Brother PJ-600 Series Command Reference

28

© 2011 Brother Industries, Ltd. All Rights Reserved.

Name

Apply/cancel proportional characters

Syntax

ESC + p + {n1}

1B H + 70 H + {n1}

Description

Applies or cancels proportional characters for alphanumeric characters.

After this command is specified, the left margin and right margin must be

specified again.

Definition of {n1}

00 H(0): Cancel proportional characters

01 H(1): Apply proportional characters

Name Auto-on/off

Syntax ESC

+

~ + A + {n1}

1B H + 7E H + 41 H + {n1}

Description

Select whether or not the print unit is automatically turned on when it is plugged

into an external power supply.

Definition of {n1}:

00 H(0):Disable

01 H(1):Enable

02 H(2):Enable(No main button)

Name

Specify Auto Power Off(AC/DC/Li-ion)

Syntax ESC

+

~ + e + t + {n1} + NUL

1B H + 7E H + 65 H + 74 H + {n1} + 00 H

Description

Select the length of time until the print unit automatically turns off when it is

plugged into an external power supply.

Definition of {n1}:

00 H(0):None

01 H(1):10 minutes

02 H(2):20 minutes

03 H(3):30 minutes

04 H(4):40 minutes

05 H(5):50 minutes

06 H(6):60 minutes