Reading multiple tracks – Brother RJ-4030 User Manual
Page 37

Raster Command Reference
- 33 -
5. MCR Command Specifications
Reading multiple tracks
Data in the above-mentioned format is combined for the specified number of tracks and sent.
Example: Reading Track 1 and Track 2
54h
31h
3Ah
[data]
0Dh
0Ah
54h
32h
3Ah
[data]
0Dh
0Ah
T
1
:
[data]
CR
LF
T
2
:
[data]
CR
LF
Condition
Failed Reception Response (Timeout)
Response
Hex
54h
30h
3Ah
[“timeout”]
0Dh
0Ah
ASCII
T
0
:
[“timeout”]
CR
LF
Character string
“timeout”
Delimiter
Description
Response indicating that it returned to the MCR off status due to a timeout
[“timeout”]: The character string “timeout” is entered.
Hex
74h
69h
6Dh
65h
6Fh
75h
74h
ASCII
t
i
m
e
o
u
t
Condition
Failed Reception Response (Read Error)
Response
Hex
54h
30h
3Ah
[“can not read”]
0Dh
0Ah
ASCII
T
0
:
[“can not read”]
CR
LF
Character string “can
not read”
Delimiter
Description
Response indicating that an error occurred while reading
[
“can not read”]: The character string “can not read” is entered.
Hex
53h
41h
4Eh
20h
4Eh
4Fh
54h
20h
52h
45h
41h
44h
ASCII
c
a
n
n
o
t
r
e
a
d
Space
Space