Temperature settings – Takagi T-H3M-IN/OS User Manual
Page 38
38
Page
Operation
Screen on the controller
1.
Turn on the 120 VAC power supply to the water
heater
2.
Press the "ON/OFF" button on the controller in
order to turn the controller on
3.
When ON, the STAND BY LED is lit
4.
It shows the set temperature on its display as shown
in the picture on the right (EX: 120 °F)
5.
Press the "HOT" button or the "COLD" button to set
the temperature setting of the unit
(EX: 120 °F)
TEMPERATURE SETTINGS
-Using Remote controller-
-Temperature setting on the PCB-
(Without Remote controller)
There are 2 preset temperatures (120 °F (49 °C) and 140 °F (60 °C)) that you can select from by changing
the DIPswitch settings on the computer board without the remote controller See the table below
When the remote controller is in normal operation, the set temperature of the remote controller is given
priority over the set temperature of the DIPswitch settings
• The temperature has been preset at the factory to 120 °F (49 °C)
Computer board
Bank of
DIPswitches
NOTE: Only change the switches with dark squares The dark squares
indicate the direction the DIPswitches should be set to
120 °F (49 °C)
DEFAULT
140 °F (60 °C)
No 9 : OFF
No 9 : ON
OFF
ON 1 2 3 4 5 6 7 8 9 10
OFF
ON 1 2 3 4 5 6 7 8 9 10
Normal Operation
Owner's Guide