-Exhaust vent (ABS, PVC, CPVC, or polypropylene vent)-

The Indoor model can be vented with ABS, PVC, CPVC, or polypropylene (temperature rated up to at

least 149 °F) Vent material certified to ULC S636 standards is recommended in the USA In Canada,

plastic venting must be certified to ULC S636 standards

• The maximum length of exhaust vent piping must not exceed 70 ft (213 m) for 3” venting, which

depends on the elevation where the water heater is installed, and 100 ft (305 m) for 4” venting

(deducting 5 ft (15 m) for each elbow used in the venting system) Do not use more than 5

elbows See the table below

• When the horizontal vent run exceeds 5 ft (15 m), support the vent run at 3 ft (09 m) intervals

with overhead hangers

Item

Material

United States

Canada

Exhaust pipe and

Fittings

Schedule 40 PVC

ANSI/ASTM D1785

ULC S636 Certified

Materials Only

PVC-DWV

ANSI/ASTM D2665

Schedule 40 CPVC

ANSI/ASTM F441

Schedule 40 ABS-DWV

ANSI/ASTM D2661

Polypropylene

UL-1738

Pipe Cement/Primer

PVC

ANSI/ASTM D2564

CPVC

ANSI/ASTM F493

ABS

ANSI/ASTM D2235

NOTE: Do NOT Use Cellular Foam Core Pipe

*For each elbow added, deduct 5 ft. (1.5 m) from max. vent length.

For details on the vent connection, refer to p 13 to 16

No. of

Elbow

2" venting

3" venting

4" venting

Up to 3,000 ft Up to 3,000 ft Up to 6,000 ft Up to 10,100 ft Up to 10,100 ft

0

65 ft (20 m)

70 ft (213 m) 40 ft (122 m)

25 ft (76 m) 100 ft (305 m)

1

15 ft (05 m)

65 ft (198 m) 35 ft (107 m)

20 ft (61 m)

95 ft (290 m)

2

N/A

60 ft (183 m)

30 ft (91 m)

15 ft (46 m)

90 ft (274 m)

3

N/A

55 ft (168 m)

25 ft (76 m)

10 ft (30 m)

85 ft (259 m)

4

N/A

50 ft (152 m)

20 ft (61 m)

5 ft (15 m)

80 ft (244 m)

5

N/A

45 ft (137 m)

N/A

N/A

75 ft (229 m)

Excludes vent terminators, termination elbows, or rain caps

Max. Vertical or Horizontal (Total) Vent Lengh