beautypg.com

Vent termination clearances, Installation installation manual – Takagi T-H3M-IN/OS User Manual

Page 17

background image

17

Page

Installation

Installation Manual

-Vent termination clearances-

Canada

USA

Direct-vent and other

than Direct-vent

Direct-

vent

Other than

Direct-vent

A Clearance above grade, veranda, porch, deck, or

balcony

1 foot

1 foot

1 foot

B Clearance to window or door that may be opened

3 feet

1 foot

4 feet from below or

side opening 1 foot

from above opening

C Clearance to permanently closed window

*

*

*

D

Vertical clearance to ventilated soffit located above

the vent terminator within a horizontal distance

of 2 feet (61cm) from the center line of the

terminator

*

*

*

E Clearance to unventilated soffit

*

*

*

F Clearance to outside corner

*

*

*

G Clearance to inside corner

*

*

*

H Clearance to each side of center line extended

above meter/regulator assembly

3 feet

*

*

I Clearance to service regulator vent outlet

3 feet

*

*

J

Clearance to non-mechanical air supply inlet to

building or the combustion air inlet to any other

application

3 feet

1 foot

4 feet from below or

side opening 1 foot

from above opening

K Clearance to mechanical air supply inlet

6 feet

3 feet

3 feet

L Clearance above paved sidewalk or paved driveway

located on public property

7 feet

*

7 feet

M Clearance under veranda, porch deck, or balcony

1 foot

*

*

*For clearances not specified in ANSI Z2231 / NFPA 54 or CAN/CSA-B1491, please use clearances in accordance

with local installation codes and the requirements of the gas supplier

INSIDE CORNER DETAIL

V

Gas meter / regulator

V

V

V

V

V

V

V

V

V

X

X

X

Vent terminal

Air supply inlet

Area where is not permitted

G

A

E

D

B

L

C

F

B

B

B

B A

J

OPERABLE

FIXED

CLOSED

B

H

M

K

OPERABLE

FIXED

CLOSED

I