beautypg.com

Takagi T-H3M-IN/OS User Manual

Page 27

background image

27

Page

Installation

Installation Manual

Remote controller

terminals

Fig. C-1

Two fork terminals

Remote controller cable

Inlet for the remote

controller cable

Cut out

Fig. C-2

3.  Tighten the two "Fork terminals" beneath the two "Remote controller terminal" screws,

which are not polarity-sensitive, on the back of the main body (Fig. C-1)

4. Cut out the inlet for the remote controller cable from the bottom of the main body (Fig. C-2)

5.  Place the “Main body” back on the "Back plate", with the "Remote controller cable" running
out of the bottom inlet

1.  Disconnect power supply from the water heater.

2.  Take off the water heater’s front cover.

3.  Locate the remote controller terminals, pictured below (located around the lower

right-hand side of the computer board)

4.  Take off the back plate from the remote controller, and then attach the two fork terminals to

connector base on the backside of the remote controller with two screws Make sure the

terminals are firmly fixed

5.  Pull the remote’s wires through the hole at the bottom of the water heater’s casing.

6.  Properly attach the remote’s wires to the remote controller terminal on the computer board

(No polarity)

* Do NOT jump or short-circuit the wires, or the computer will be damaged.

7.  Replace Front Cover securely.

8.  Wires used for the remote controller connection must be:

• Minimum 20 gauge wire (No polarity)

• Maximum 400 ft (122 m) long

9008172005 (TM-RE40)

Connect other end to these terminals