Maintenance – Prochem Blazer XL User Manual
Page 33
MAINTENANCE
86037390 02/14/07
4-8
NITROGEN ACCUMULATOR
The nitrogen accumulator is pressurized to 250 PSI
and must be replaced periodically. The accumulator
cannot be repaired or recharged. We recommend
replacement every 1000 hours (or yearly) of use.
PRESSURE REGULATOR
Lubricate the o-rings and bullet every 50 hours.
Use o-ring lubricant Part #86265430, PRV NO.
05-008035.
For the procedure, see the "General Service
Adjustments” section in this manual for details.
VACUUM HOSES
To assure maximum hose life, we recommend that
the hoses be washed out with clean water at the end
of each working day.
HIGH PRESSURE HOSES
Inspect your high pressure hoses for wear after
the first 100 hours of use. Inspect every 25 hours
thereafter. If hoses show any signs of damage or
impending rupture, replace the hose.
DO NOT attempt to
repair high pressure
hoses! Repairing high pressure hoses may
result in severe burns and serious injury!
All high pressure hoses must be rated for 3000
PSI at 250°F. Thermoplastic hoses do not meet
these specifications and should not be used.
Severe burns and injury may result if the hoses
do not meet these requirements.
OPTIONAL WASTE PUMP-OUT
At the end of each work day, make certain that you
remove any debris or sediment which may be inside
the waste pump by pumping fresh water through the
pump.