Specifications, Characteristics & requirements, Table 3-1: performance characteristics – PNI SeaTRAX User Manual
Page 8: 3specifications, 1 characteristics & requirements
PNI Sensor Corporation
DOC#1018154 r02
SeaTRAX User Manual
Page 3
3
Specifications
3.1
Characteristics & Requirements
Table 3-1: Performance Characteristics
1
Parameter
Value
Heading
Accuracy
≤65° of pitch after full range calibration <0.3° rms
≤80° of pitch
after full range calibration <0.5° rms
≤5° of pitch after 2D calibration
<2.0° rms
≤2 times the calibration tilt angle when
using limited-tilt calibration
2
<2.0° rms
Resolution
0.1°
Repeatability
0.05° rms
Attitude
Range
Pitch
± 90°
Roll
± 180°
Accuracy
Pitch
0.2° rms
Roll
≤65° of pitch
0.2° rms
≤80° of pitch
0.4° rms
≤86° of pitch
1.0° rms
Resolution
0.01°
Repeatability
0.05° rms
Maximum Operational Dip Angle
3
85°
Magnetometers
Calibrated Field Range
± 125 µT
Resolution
0.05 µT
Repeatability
± 0.1 µT
Footnotes:
1. Specifications are subject to change. Assumes the SeaTRAX is motionless and the local
magnetic field is clean relative to the user calibration.
2. For example, if the calibration was performed over ±10° of tilt, then the SeaTRAX would provide
<2° rms accuracy over ±20° of tilt.
3. Performance at maximum operational dip angle will be somewhat degraded.