6.4.3

Current Configuration

These indicators mimic the pertinent selections made on the Configuration tab.

6.4.4

Options

This window indicates how many samples are to be taken and provides real time heading,
pitch, and roll information if “HPR During Calibration” is set to , both as defined
on the Configuration tab.

Audible Feedback

If selected, SeaTRAX Studio will give an audible signal whenever a calibration

sample point is taken.

6.4.5

Clear

Clear Mag Cal to Factory

This button clears the user’s calibration of the magnetometers. Once selected, the

module reverts to its factory magnetometer calibration. To save this action in

nonvolatile memory, click the button. It is not necessary to clear the current

calibration in order to perform a new calibration.

Clear Accel Cal to Factory

This button clears the user’s calibration of the accelerometer. Once selected, the
module reverts back to its factory accelerometer calibration. To save this action in

non-volatile memory, click the button. It is not necessary to clear the current

calibration in order to perform a new calibration.