I/o specifications, Power specifications, Environmental specifications – PNI TCM 5 User Manual
Page 6: 6 i/o specifications, 7 power specifications, 8 environmental specifications
PNI Sensor Corporation
Doc #1007537 r12
TCM3 & TCM5 User Manual- Sept 2011
Page 6
2.1.6 I/O Specifications
Parameter
TCM3
TCM5
Units
Time to Initial Good Data from
Power On
1
<210
<210
msec
Time to Initial Good Data from
Sleep Mode
1
<80
<80
msec
Maximum Sample Rate
2
~30
~30
samples/sec
RS-232 Communication Rate
300 to 115200
300 to 115200
baud
Output Formats
Binary High Performance Protocol
[1]
FIR taps set to “0”.
[2] The maximum sample rate is dependent on the strength of the magnetic field, and typically will be from 25 to 32
samples/sec.
2.1.7 Power Specifications
Parameter
TCM3
TCM5
Units
Supply Voltage
3.8 to 5 V (unregulated)
3.8 to 5 V (unregulated)
VDC
Current Draw at
maximum sample rate
20 typical
20 typical
mA
Sleep Mode
0.6 typical
0.6 typical
mA
2.1.8 Environmental Specifications
Parameter
TCM3
TCM5
Units
Operating Temperature
-40º to 85º
-40º to 85º
C
Storage Temperature
-40º to 85º
-40º to 85º
C