Component Identifiers
Component
DataComponentID
(decimal)
Format
Units
Range
kHeading
5
Float32
degrees
0.0˚ to 359.9˚
kTemperature 7
Float32
˚ Celsius
-
40˚ to 85˚
kDistortion
8
Boolean
True or False
False (Default) =
no distortion
kCalStatus
9
Boolean
True or False
False (Default) =
not calibrated
kPCalibrated
21
Float32
G
-1.0 to 1.0
kRCalibrated
22
Float32
G
-1.0 to 1.0
kIZCalibrated
23
Float32
G
-1.0 to 1.0
kPAngle
24
Float32
degrees
-
90.0˚ to 90.0˚
kRAngle
25
Float32
degrees
-
180.0˚ to 180.0˚
KXAligned
27
Float32
T
KYAligned
28
Float32
T
KZAligned
29
Float32
T
Component Types for kSetDataComponents & kDataResp frames
kHeading
Compass heading output.
kTemperature
This is sampled from the internal temperature sensor of the module. Its value is in °
Celsius and has an accuracy of +/- 3° C.
kDistortion Read only flag that indicates that at least one magnetometer axis reading is beyond +/- 80
µT.
kCalStatus Read only flag that indicates user calibration status. False (Default) = Not calibrated.
kPCalibrated, kRCalibrated & kIZCalibrated
F
actory calibrated Earth’s acceleration vector (G)
component output.
kPAngle, kRAngle
Pitch and Roll angle outputs. Pitch is equal to -90.0
˚ to 90.0˚ and Roll is equal to
-
180.0˚ to 180.0˚.
kXAligned, kYAligned, kZAligned
User calibration Earth’s magnetic field (M) vector component
output.