5.1.3.2 Replace the rotor

When the minimum rotor size s

min

according to 3.2.2.4 is reached, a re-adjustment of the air

gap “a” is no longer possible and the rotor has to be replaced. An operative readiness of the
brake in certain cases falling below the minimum rotor size does not change the above
statement; in such a case “a proper use” is no longer existing.

ÎStop!

Even after an exchange of the rotor, the complete braking torque will only be effective
after the brake linings at the rotor have run in!

Î For deviation values to M

bN

: see 3.2.2.1

ÎAttention!

During the task of replacing the rotor, all the mechanical parts associated with the
transmission of the braking torque have to checked for excessive wear (armature disc,
hollow screws) and/or integrity (springs) and, if required, to be replaced

!




5.2 Brake out of Operation (Malfunctions)

The following table includes typical problems during commissioning or running in, their possible
causes and instructions on solving them.

Malfunction Possible

causes

Solution

.


Brake does not

Air gap too large

Check and readjust air gap

release

Brake is not supplied

Check electrical

with

voltage

connection

Voltage at the coil

Check the supply voltage

too low

of the coil

Armature plate obstructed

Remove obstruction



Brake

releases

Air gap too large

Check and readjust air gap

with

delay

Voltage at the coil

Check the supply voltage

too low

of the coil

Brake does not

Voltage at the coil

Check the supply voltage

apply

too large

of the coil


Armature plate obstructed

Remove obstruction



Brake applies

Voltage at the coil

Check the supply voltage

with

delay

too large

of the coil