4-Pin Connection Port (SG Models):


Older models of the IPM500 Series (MROHHHSG, MROJR2SG) differ from the newer models in two ways.
One, the connection port on the rear of the meter and two, the type of input required for the setup of the
meter.

Connection Port
Shown below is the back of the older D500 series. The difference being that the newer connection ports
are 6-pin while this port is a 4-pin connection. The power/input connections are shown in the left picture
below. These connections are constant for the entire series of meters (old/new).



Input Requirements
When using a 4-pin connection meter model it is important to remember that your input type will be
different than meters with the 6-pin connection ports. The input configuration type and range are listed
below, along with brief directions.

1. Press the left Menu button until InPut appears on the display
2. Press the Peak button until the display reads rAtIo
3. Press Reset until 0.20U appears
4. Press the left Menu button to store your selections, SEtuP will appear.

This is the only difference in configuration of the two types of meters. It is also important to remember
that the directions/pictures on the web (www.futek.com) are written for the 6-pin connection port meters.
While the directions are correct for both types of meters (with the exception of the variation of input,
above), the internal jumpers may be located in different places for the 4-pin connection port. Please
refer to your Owner’s Manual for additional information.