TIMER + COUNTER MIXED MODE SETTINGS

Parameter Configuration
PV

SV

FUnC

miX

Sets the controller to function as a timer and counter.

T mode

Timer Mode sets the timer to count up or Down.

T otmd

Timer Output Mode sets the output timing functions. See the
timing functions section on page 9 for detail description of each
timing function.

t Unit

Sets the display units of measure. See table A on page 8 for a list
of the available units.

C inPt

Counter input mode can be selected to count up or down when a
counter input signal is received.

UP

The present value will increase with each counter input
signal.

doun

The present value will decrease with each counter input
signal.

C otmd

Counter Output Mode determines the output operation of the
control. It also determines how the counter will function after
reaching the set point. See the output function tables on page 13
for more information.

C SPEd

Counting Speed can be set from one count per second up to
10,000 counts per second. This setting determines the minimum
input signal width.

t oUt1

Sets the pulse width (t) for output 1.

t oUt2

Sets the pulse width (t) for output 2.

Point

Sets the number of digits to the right of the decimal point on the
display.

PSCALE

Pre-Scale is used when converting the process value’s units of
measure. The pre-scale value would be set as the conversion factor.
(Pv = Pv * PSCALE).