Counter Output Mode determines the output operation of the
control. It also determines how the counter will function after
reaching the set point. See the output mode charts on page 13 for
more information.

C SPEd

Counting Speed can be set from one count per second up to
10,000 counts per second. This setting determines the minimum
input signal width.

t oUt1

Sets the pulse width (t) for output 1.

t oUt2

Sets the pulse width (t) for output 2.

Point

Sets the number of digits to the right of the decimal point on the
display.

PSCALE

Pre-Scale is used when converting the process value’s units of
measure. The pre-scale value would be set as the conversion factor.
(Pv = Pv * PSCALE)

PwErS

Power Save feature allows the control to save the current process
value upon loss of power.

SAvE

Save process value upon power loss

CLEAr

Clear process value upon power loss

rtSr

Minimum width of reset signal determines how long the reset
terminals must be engaged to reset the device.

inPtLC

Input signal can be set for PNP or NPN. This parameter
determines which wiring diagram should be used.