Symptom

Possible Cause(s)

Corrective Action

Troubleshooting Chart

Motor will not run

Motor runs hot and
overload kicks off

Motor runs but no
water is delivered
Note: Check prime
before looking for
other causes. Unscrew
priming plug and see if
water is in priming
hole.

Pump does not deliver
water to full capacity

1. Disconnect switch is off
2. Fuse is blown
3. Starting switch is defective
4. Wires at motor are loose,

disconnected or wired
incorrectly

1. Motor is wired incorrectly
2. Voltage is too low

3. Pump house not properly

vented

1. Pump in new installation

did not pick up prime
through:
a. Improper priming
b. Air leaks
c. Leaking foot valve

2. Pump has lost prime

through:
a. air leaks
b. water level below suc-

tion of pump

3. Impeller is plugged
4. Check valve or foot valve

is stuck in closed position

5. Pipes are frozen

6. Foot valve and/or strainer

are buried in sand or mud

1. Water level in well is

lower than estimated

2. Steel piping (if used) is

corroded or limed, causing
excess friction

3. Piping is too small in size

1. Be sure switch is on
2. Replace fuse
3. Replace starting switch
4. Refer to wiring instructions. Check and tighten all wiring

Capacitor voltage may be hazardous. To
discharge capacitor, touch short capacitor

terminals with an insulated screwdriver. BE SURE to hold handle
of screwdriver while making contact with capacitor terminals.

1. Refer to wiring instructions
2. Check with power company. Install heavier wiring if wire size

is too small (See wiring chart)

3. Be sure pump has sufficient ventilation to cool the motor

1. New installation:

a. Re-prime according to instructions
b. Check all connections on suction line
c. Replace foot valve

2. Existing installations:

a. Check all connections on suction line and shaft seal
b. Lower suction line into water and re-prime. If receding

water level in well exceeds suction lift, a deep well pump is
needed

3. Clean impeller
4. Replace check valve or foot valve

5. Thaw pipes. Bury pipe below frost line. Heat pit or pump

house

6. Raise foot valve and/or stainer above well bottom

1. A deep well jet pump my be needed (over 25 ft. (7.6M) to

water)

2. Replace with plastic pipe where possible, otherwise with new

steel pipe

3. Use larger piping

Operating Instructions and Parts Manual

BWLS Series

5

www.blueangelpumps.com